Micronic Rack Reader DR505
The Micronic Rack Reader DR505 features a passive anti-frost system, which enables users to read racks filled with 2D codes tubes straight from the freezer.
The Micronic Screw Cap Recapper CS700 line offers users the ability to cap, decap or recap 96 (model CS700), 48 (model CS710) or 24 (model CS720) tubes with Screw Caps in a single action. Designed to improve efficiency, the Micronic Screw Cap Recapper can be used as a stand-alone instrument or be simply integrated into a fully automated laboratory environment. The CS700 decaps Screw Caps from a full tube storage rack in less than 30 seconds! Through the graphical touch screen interface the operator is able to select any rack to cap, decap or recap without using different adapters for different tube sizes. The Screw Cap Recapper uses a precisely determined torque value for optimal sealing quality thereby minimizing sample evaporation and maximizing the integrity of your valuable samples. Additionally, the CS710 and CS720 Recappers are now standard equipped with a Tube Detection Sensor giving even more reliability to the user-friendly recapper.
Micronic offers the CS700 line for use with other brands of tubes and caps (Thermo, FluidX and LVL). This means that if you use sample storage tubes or caps from another brand, it is still possible to benefit from the wide range of qualities our recapper offers.
Benefit now from receiving a labware voucher worth €2000/$2000 with the purchase of a Micronic CS700!
(Valid through December 31st, 2024)
Micronic labware is manufactured and assembled in-house in a NEN-EN-ISO14644-1 Class 7 certified clean room environment (which is comparable to the US Federal Standard 209E Class 10,000).
For the manufacturing of its long term sample storage labware products Micronic uses solely virgin plastic raw material. The raw materials and auxiliary agents are selected based on the specifications that satisfy the high quality requirements of our products. The materials are FDA approved and comply with the (USA) USP XXII tests, including class VI (Medical approved), and the European Pharmacopoeia-monograph 3.2.2 unless communicated otherwise. Material components used to produce Micronic labware can be traced via the lot number indicated on the packaging.
The materials used for Micronic tubes are the result of extensive research. One selection criterion is that the amount of measurable extractables leaching into samples is minimized.
By maintaining the highest possible hygiene level during our production processes, Micronic manufactured labware is free of any detectable RNase or DNase contamination and the endotoxin level of produced and packaged labware is limited to an acceptable minimum (< 0.01 EU/ml). Our products are periodically tested on RNase, DNase and their endotoxin levels by independent expert organizations.
The Micronic 2D Data-Matrix codes and 1D barcodes are produced conform industry standards. The 2D Data-Matrix code (which adheres to the ECC200 standard) and 1D barcode (type 128B) are laser-etched into the code area and are guaranteed unique.
Products produced by Micronic are tested according to AQL inspection level G2 and AQL value 0.4.
Micronic Sample Storage tubes are classified as general laboratory products according to leading European Life Science Organizations (GAMBICA, FHI, LABMAS, Laborama, SPECTARIS). More information can be found here.
Upon request, Micronic products can be supplied gamma irradiated or ethylene oxide treated.
Our products comply with the IATA requirements for the transport of diagnostic specimens (UN packing instruction 602 and 650), assuming that our products are properly used (closed).
If you have any additional questions on the quality and safety of our products, please feel free to contact Micronic at sales@micronic.com.
To enhance and accelerate the capping and decapping process, the Micronic (De)Capping line provides you with several options. The Screw Cap Recapper CS100 is developed to improve the manual (de)capping of tubes. The cost-effective tools are set to a precise torque value and stop turning when a perfect seal is established, ensuring an optimal sealing performance. Developed in conjunction with several leading laboratories, the Screw Cap Recapper CS500 offers the ability to cap, decap or recap a row of tubes in less than 5 seconds and a whole rack in only 1 minute. This is 10 times faster than by hand and improves productivity. The automated Screw Cap Recapper CS700 is “must-have” equipment for higher throughput users. The devices are user-friendly and extremely durable and reliable and cap entire racks in 30 seconds.
Micronic received a Good Industrial Design Award (GIO award) for the innovative design of the recapper. The award indicates that the recapper is original, functional, ergonomic, designed with respect for the environment and adds value to end-users.
Parameter | Screw Cap Recapper CS700 |
---|---|
Rack compatibility | ANSI / SLAS standard 96-format |
Cycle time | 30 seconds |
Dimensions | 590 x 251 x 460 mm |
Voltage | 115 - 230 V |
Article Number | Description | Unit Size |
---|---|---|
MP35462 | Micronic Screw Cap Recapper CS700 TDS for Micronic Screw Caps (TRE) (price including 5 cap carriers free of charge) | 1 unit |
MP35463 | Micronic Screw Cap Recapper CS700 TDS for Micronic Screw Caps IG (TRE) (price including 5 cap carriers free of charge) | 1 unit |
MP35464 | Micronic Screw Cap Recapper CS700 TDS for Micronic Screw Caps (TRI) (price including 5 cap carriers free of charge) | 1 unit |
MP35465 | Micronic Screw Cap Recapper CS700 TDS for Micronic Low Profile Screw Caps (TRI) (price including 5 cap carriers free of charge) | 1 unit |
MP35472 | Micronic Screw Cap Recapper CS710 TDS for Micronic Screw Caps (TRE) (price including 5 cap carriers free of charge) | 1 unit |
MP35473 | Micronic Screw Cap Recapper CS710 TDS for Micronic Screw Caps (TRI) (price including 5 cap carriers free of charge) | 1 unit |
MP35477 | Micronic Screw Cap Recapper CS720 TDS for Micronic Screw Caps (TRE) (price including 5 cap carriers free of charge) | 1 unit |
MP35478 | Micronic Screw Cap Recapper CS720 TDS for Micronic Screw Caps (TRI) (price including 5 cap carriers free of charge) | 1 unit |
The Micronic Rack Reader DR505 features a passive anti-frost system, which enables users to read racks filled with 2D codes tubes straight from the freezer.
The handheld device offers users the ability to cap, decap or recap a row of 8, 6 or 4 tubes in less than 5 seconds – 10 times faster than by hand!
To address the need for low volume genomics, the 0.30ml tube enables miniaturization of reaction volume. Working volume with Screw Cap (+21ºC): 0.32ml (V-bottom) and 0.23ml (Vr-bottom).
The transparent tube walls enable easy visual checking, while the 4 coding concepts guarantee sample traceability. Working volume (+21°C): 1.20ml with Screw Cap.